Power Integrations are now offering an amazing circuit implementations in power supply chips. Everything including high-voltage MOSFET, PWM controller, soft start-up circuit, oscillator, programmable current limit circuit, short-circuit and open-loop protection, gate drive for the switching MOSFET, feedback compensation circuit and thermal shutdown reducing the assembly costs. |
|
|
Power Integrations EcoSmart® IC technology enables power supply designers to meet the requirements of all existing and proposed energy efficiency standards worldwide. For the latest in energy efficiency guidelines and design solutions, visit the Power Integrations Green Room at www.powerint.com/greenroom. |
|
|
Features |
Download |
|
|
Product Selector Guide - AC-DC Products
|
|
|
|
Product Selector Guide - DC-DC Products
|
|
|
|
|
2007 Data Book and Design Guide
|
|
Design Tools
|
PI Expert™ Design Software Suite v.6.5 includes the following software tools that simplify the design of off-line power supplies and DC-DC converters based on products from Power Integrations. |
|
|
PI Expert - A powerful software program that takes a designer’s switching power supply requirements and determines the critical components needed to generate a working switch mode power supply, including the transformer design. A design can be optimized for efficiency or cost using auto design or manual control options.PI Xls Designer - provides design spreadsheet support for recently introduced Power Integrations ICs not yet included in the PI Expert Design Software tool, as well as providing a simplified spreadsheet approach for other PI products for advanced users who prefer a spreadsheet interface.PI Transformer Designer is a tool that generates detailed instructions needed by transformer vendors to construct a transformer based on designs created with PI Expert Design Software and PI XLS Designer. Intelligent shield selection is included to simplify the task of meeting EMI standards, with optimized bobbin pin assignment for ease of layout. |
PI Expert™ Design Software Suite v.6.5
To download or request a CD, go to |
|
AC/DC PRODUCTS |
|
|
|
|
|
I. VERY LOW POWER AC-DC, NON-ISOLATED LINEAR/PASSIVE SUPPLY REPLACEMENT (<360 mA) |
|
Product 1,5 |
||||||
|
LNK302 P or G |
LNK304 P or G |
LNK305 P or G |
LNK306 P or G |
|||
|
Output Current9 |
MDCM7 |
230 VAC ± 15% |
63 mA | 120 mA | 175 mA |
225 mA |
|
CCM8 |
80 mA | 170 mA | 280 mA | 360 mA | ||
|
Output Current9 |
MDCM7 |
85-265 VAC |
63 mA | 120 mA | 175 mA | 225 mA |
|
CCM8 |
80 mA | 170 mA | 280 mA | 360 mA | ||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | ||
|
Switching Frequency (kHz) |
66 | 66 | 66 | 66 | ||
|
Control Method |
ON/OFF | ON/OFF | ON/OFF | ON/OFF | ||
|
Self-Powered4 |
Y | Y | Y | Y | ||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
N.R. | N.R. | N.R. | N.R. | ||
|
Adjustable Current Limit |
- | - | - | - | ||
|
Auto Restart |
- | Y | Y | Y | ||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | ||
|
Frequency Jitter |
Y | Y | Y | Y | ||
|
Power Limiting |
Y | Y | Y | Y | ||
|
Line UV Detection |
- | - | - | - | ||
|
Line OV Detection |
- | - | - | - | ||
|
Remote ON/OFF |
Y | Y | Y | Y | ||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | ||
|
Max. Duty Cycle % (DCMAX) |
69 | 69 | 69 | 69 | ||
|
Simultaneous Line Sensing and Current Limit |
- | - | - | - | ||
|
Price |
![]() |
![]() |
![]() |
![]() |
||
Notes
|
II. VERY LOW POWER AC-DC POWER CONVERSION (UP TO 9 W) |
|
Product 1,5 |
||||||||||||||
|
P or G |
P or G |
P or G |
P or G6 |
P or G6 |
P or G6 |
LNK362 P or G |
LNK363 P or G |
LNK364 P or G |
||||||
|
Continuous Output Power9 |
Adapter2 |
230 VAC ±15% |
1.9 W |
2.5 W |
3 W |
4 W |
4 W |
4 W |
2.8 W |
5 W |
5.5 W |
|||
|
Open Frame3 |
1.9 W | 2.5 W | 3 W | - | - | - | 2.8 W | 7.5 W | 9 W | |||||
|
Continuous Output Power9 |
Adapter2 |
85-265 VAC |
1.9 W | 2.5 W | 3 W | 3 W | 3 W | 3 W | 2.6 W | 3.7 W | 4 W | |||
|
Open Frame3 |
1.9 W | 2.5 W | 3 W | - | - | - | 2.6 W | 4.7 W | 6 W | |||||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | |||||
|
Switching Frequency (kHz) |
66 | 83 | 100 | 42 | 42 | 42 | 132 | 132 | 132 | |||||
|
Control Method |
ON/OFF | ON/OFF | ON/OFF | PWM | PWM | PWM | ON/OFF | ON/OFF | ON/OFF | |||||
|
Self-Powered4 |
Y |
Y |
Y |
- |
- |
- |
Y |
Y |
Y |
|||||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
N.R. | N.R. | N.R. | Y | Y | Y | N.R. | N.R. | N.R. | |||||
|
Adjustable Current Limit |
- | - | - | - | - | - | - | - | - | |||||
|
Auto Restart |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |||||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | |||||
|
Frequency Jitter |
Y | Y | Y | Y | Y | Y | ||||||||
|
Power Limiting |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |||||
|
Line UV Detection |
- |
- | - | - | - | - | - | - | - | |||||
|
Line OV Detection |
- | - | - | - | - | - | - | - | - | |||||
|
Remote ON/OFF |
Y | Y | Y | Y | Y | Y | ||||||||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |||||
|
Max. Duty Cycle % (DCMAX) |
69 | 69 | 69 | 77 | 77 | 77 | 60 | 60 | 60 | |||||
| Simultaneous Line Sensing and Current Limit | - | - | - | - | - | - | - | - | - | |||||
|
Price |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
|
III. LOW POWER AC-DC POWER CONVERSION (UP TO 36.5 W) |
|
IV. SUPER PEAK AC-DC POWER CONVERSION (UP TO 68 W CONTINUOUS, 117 W PEAK) |
|
Product 1,5 |
|||||||||
|
PKS603 P |
PKS604 P |
PKS604 Y or F |
PKS605 P |
PKS605 Y or F |
PKS606 P |
PKS606 Y or F |
|||
|
Continuous Output Power9 |
Adapter2 |
230 VAC ± 15% |
13 W | 23 W | 35 W | 31 W | 46 W | 35 W | 68 W |
|
Adapter Peak10 |
32 W | 56 W | 56 W | 60 W | 79 W | 66 W | 117 W | ||
|
Continuous Output Power9 |
Adapter2 |
85-265 VAC |
9 W | 16 W | 23 W | 21 W | 30 W | 25 W | 45 W |
|
Adapter Peak10 |
25 W | 44 W | 44 W | 44 W | 58 W | 46 W | 86 W | ||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | ||
|
Switching Frequency (kHz) |
277 | 277 | 277 | 277 | 277 | 277 | 277 | ||
|
Control Method |
ON/OFF | ON/OFF | ON/OFF | ON/OFF | ON/OFF | ON/OFF | ON/OFF | ||
|
Self-Powered4 |
- | - | - | - | - | - | - | ||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
N.R. | N.R. | N.R. | N.R. | N.R. | N.R. | N.R. | ||
|
Adaptive Current Limit |
Y | Y | Y | Y | Y | Y | Y | ||
|
Auto Restart |
Y | Y | Y | Y | Y | Y | Y | ||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | ||
|
Frequency Jitter |
Y | Y | Y | Y | Y | Y | Y | ||
|
Power Limiting |
Y | Y | Y | Y | Y | Y | Y | ||
|
Line UV Detection |
Y | Y | Y | Y | Y | Y | |||